Add to Cart
SCA141/142 relay signal output angle alarm switch , tilt alarm sensor
SCA141&SCA142 | CONDITIONS | PARAMETERS | UNIT |
Measure rang | ±15 | ° | |
Measure axis | X Y | Axis | |
Resolution | 0.01 | ° | |
Measure accuracy | 0.05 | ° | |
Long term stability | 0.05 | ° | |
Zero Temp. coefficient | -40~85℃ | ±0.006 | °/℃ |
Sensitivity temp. coefficient | -40~85℃ | ≤100 | ppm/℃ |
Power on time | 0.1 | S | |
Response time | 0.2 | s | |
EMC | According to EN61000 and GBT17626 | ||
MTBF | ≥50000 hours/times | ||
Insulation Resistance | ≥100M | ||
Shockproof | 100g @ 11ms,3 axial direction (half sinusoid) | ||
Anti-vibration | 10grms,10~1000Hz | ||
Protection glass | IP67 | ||
Cables | Standard 1M length/wearproof/grease proofing/wide temp./Shielded cables 4*0.4mm2 | ||
Weight | 120g(without cable) |